    A/C & heater

    Re: '98 Ford F-150. The a/c will be working for a good while then something shuts it down and the heater begins to work. I can hear something inside the panel area open or close when this happens.

  2. #2
    Senior Member
    Join Date
    Oct 2012
    Name
    Ryan
    Location
    CA
    Posts
    16,020
    What's your temp gauge look like? Does it start moving towards hot right before this happens?

  3. #3
    Junior Member
    Join Date
    Feb 2014
    Name
    john
    Location
    mcallen
    Posts
    10
    It cools great but then something sounds like it shuts or closes and the heater comes on. The sound is like a suction then it closes bringing on the hot air. I tried messing with the switch that changes ac to panel and then off and floor. It seems to work. After awhile of messing with it works again. Its like if there is something that closes and changes to heater.

  4. #4
    Senior Member
    Join Date
    Oct 2012
    Name
    Ryan
    Location
    CA
    Posts
    16,020
    Is there any clicking noise or anything in the dash when this happens as well? If so, it sounds like your blend door actuator is malfunctioning. It closes off the A/C vents and opens up the heater vents (that would be the closing and suction sounds you are hearing).

  5. #5
    Junior Member
    Join Date
    Feb 2014
    Name
    john
    Location
    mcallen
    Posts
    10
    Yes that is exactly what it does. Closes the a/c and opes up the heater. So this blend door actuator is what needs replacing?

  6. #6
    Senior Member
    Join Date
    Oct 2012
    Name
    Ryan
    Location
    CA
    Posts
    16,020
    Sounds like the culprit then, and I'm not entirely sure since HVAC is not my specialty. However, if Joe Grasso would like to chime in, or Alex, they know more on this issue.

  7. #7
    Da Professuh Raptor05121's Avatar
    Join Date
    Jan 2012
    Name
    Alex
    Location
    Live Oak, FL
    Posts
    1,444
    Sounds like a blend door. It is controlled by vacuum lines. So either the door or module is faulty or your vacuum lines are failing. Ford designed the HVAC for the fail-safe setting to go to defrost. (IE if your system failed, it goes to defrost so you can still see out of your windows)
    4.2L V6 - M5OD | SCT XCal 3 @ JawsRacing | K&N Series-77 | 16" Dual Efans | Magnaflow High-Flows
    50W 5000K FX-R Projectors | Philips LumiLED Taillights | 60" Plasmaglow Fire & Ice | 2" Drop Shackles

  8. #8
    Chief Moderator Jersey_Joe's Avatar
    Join Date
    Jul 2012
    Name
    Joey
    Location
    New Jersey
    Posts
    19,016
    I agree with the professor above me ^. I had a 03 and the same thing happined. Also it would not go through the controls. It would only go on defrost. Air too. The blend door is usually the problem. However. The entire dash needs to come out. There r plenty of YouTube videos on how too. That's how I did it.

    ----------

    Took me about 6 hrs start to finish.

  9. #9
    Junior Member
    Join Date
    Feb 2014
    Name
    john
    Location
    mcallen
    Posts
    10
    Thank you gentlemen. Your knowledge is very welcomed by me and everyone else. Have a great day!

  10. #10
    Chief Moderator Jersey_Joe's Avatar
    Join Date
    Jul 2012
    Name
    Joey
    Location
    New Jersey
    Posts
    19,016
    Most welcome. Let us know how u make out bud

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •